Scope of Application
【Operating Instructions】
[Scope of Application]Used for determining the horizontal burning performance of various textile fabrics, expressed by the rate of flame propagation.
[Compliance Standards]FZ/T 01028; ASTM D 5132; JIS D 1201, etc.
[Technical Specifications]
Ignition Timing: Presettable from 0.1 s to 999.9 s; Standard ignition time is 15 s.
Burner Diameter: φ9.5 mm.
Burning Time Range: 0.1 s to 999.9 s.
Flame Height: Adjustable from 15 mm to 65 mm; Standard flame height is 38 ± 2 mm.
Gas Source: Industrial propane or butane gas; Standard safety gas cylinder included.
Reduced Pressure: Adjustable from 1 KPa to 18 KPa.
Ignition Method: Automatic ignition.
Power Supply: AC 220V, 50Hz.
Power: 50 W.
Dimensions: 540 × 350 × 460 mm.
Net Weight: 25 kg.