Scope of Application
【Operating Instructions】
YS5006V‑V20 Low‑Temperature Cold Resistance Flex Tester (Fabric Model)
【Scope of Application】
The low‑temperature cold resistance tester is specially designed to test the requirements under
various low‑temperature environments for materials such as shoe upper leather, finished shoes,
rubber, shoe soles, synthetic leather, and plastic finished shoes, in order to understand the adaptability
of various materials or finished shoes to cold climates or cold terrain areas. The instrument is made entirely of
stainless steel (SUS) and can be equipped with various test fixture devices to meet the requirements of different test standards.
**【Applicable Standards】**
ASTM D 1790, D 1593, 1052; JIS K6545; EN ISO 20344; HG/T 2411, HG/T 2871; GB/T 20991;
CNS 7705; QB/T 2224, QB/T 1471; DIN 53351; Adidas GE‑24, Adidas GE‑57; SATRA TM92, SATRA TM 161
**【Technical Parameters】**
**1. Inner and Outer Chamber Material:** Stainless steel #304
**2. Controller:** Japanese Omron controller
**3. Temperature Range:**
a. Ambient to –30°C
b. Ambient to –60°C
**4. Optional Internal Chamber Actions:**
**A. Low‑Temperature Flex Fixture for Shoe Upper Materials:**
- Number of stations: 6
- Test frequency: 1.5 ± 0.1 Hz
- Fixture V‑angle: 40° ± 1°
- Radius of curvature at the V‑tip: 6.4 mm
- Maximum distance between two fixtures: 28.5 ± 1.0 mm
- Minimum distance between two fixtures: 9.5 ± 1.5 mm
**B. Low‑Temperature Flex Fixture for Shoe Upper Materials (alternative):**
- Number of stations: 4
- Test frequency: 100 ± 5 cycles/min
- Flex angle: 22.5° ± 0.5°
**5. Safety Devices:** Thermal protection (shutdown), leakage protection (shutdown),
over‑temperature protection, overload protection, etc.
**6. Control Accuracy:** ±0.5°C
**7. Temperature Uniformity:** ±2°C
**8. Cooling Rate:**
a. Ambient to –30°C — approx. 45 min
b. Ambient to –60°C — approx. 60 min
**9. Refrigerant:** R404 (environmentally friendly)
**10. Compressor:** French Tecumseh
**11. Compressor Start Delay:** 5 min
**12. Power Consumption:** 4 kW
**13. Insulation Material:** Rigid polyurethane foam and glass wool
**14. Counter:** LCD, 0–999,999 (adjustable)
**15. Viewing Window:** 210 × 35 × 270 mm, double vacuum glazing
**16. Window Lamp:** P1 lamp, 5 W
**17. Power Supply:** AC 380 V, 50 Hz
**18. Motor:** Beltless, multi‑stage imported gear reduction motor
**19. Inner Chamber Dimensions:** 60 × 60 × 55 cm
**20. Overall Dimensions:** 110 × 105 × 160 cm
**21. Weight:** Approx. 420 kg