YS108 Safety Helmet Electrical Insulation Performance Tester
Search

YS108 Safety Helmet Electrical Insulation Performance Tester

Scope of Application

【Operating Instructions】

    This equipment is developed according to the new national standard GB/T 2812-2006 "Test Methods for Safety Helmets". It is used to detect the electrical insulation performance of safety helmets. With high automation and easy operation, it is widely used in safety helmet manufacturing enterprises and major quality inspection institutions.

 

YS108 Safety Helmet Electrical Insulation Performance Tester

Applicable Scope

This equipment is developed according to the new national standard GB/T 2812-2006 "Test Methods

 for Safety Helmets". It is used to detect the electrical insulation performance of safety helmets. With 

high automation and easy operation, it is widely used in safety helmet manufacturing enterprises and 

major quality inspection institutions.

Compliance Standards

  • GB/T 2812-2006 Test Methods for Safety Helmets

  • GB/T 2811-2007 Safety Helmets

Instrument Features

  1. Plastic water tank, solving conductivity problems associated with stainless steel and metal tanks.

  2. LED digital display for current and voltage values.

  3. Electrical insulation test head forms can be configured according to customer requirements.

  4. LED digital display for current and voltage values.

Technical Parameters

  1. Ammeter indication error: ±1%

  2. Voltmeter indication error: ±1%

  3. Timer indication error: ±1%

  4. Probe diameter: 4mm, with a hemispherical tip.

  5. Voltage increases to 1200V ± 25V within 1 minute and is maintained for 15 seconds.

  6. Voltage regulator: Range of 1500V

  7. Water tank.

  8. LED digital display for current and voltage values.